{"product_id":"switchboard-matting-5mm-electrical-insulation-7500v-ribbed-pvc","title":"Switchboard Matting – 5mm Extra-Thick Electrical Insulation Mat, 7,500 V AC Working Voltage (ASTM D178 Class 1), Broad-Rib Anti-Slip PVC | 10m × 1m Rolls, 4 Colours","description":"\u003ch2 class=\"hidden mb-8 text-3xl font-medium leading-snug tracking-tight text-gray-900 md:block\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eThe mat that stands between an engineer and 7,500 volts — extra-thick insulating PVC laid in front of every switchboard, panel and control cabinet.\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"mb-8 text-lg richtext story-text\"\u003e\n\u003cp\u003eAnyone who opens a live panel is standing on the one thing that decides whether a fault goes to ground through the floor or through them. Concrete, steel deck and damp screed all conduct. This matting does not. Laid along the front of switchgear, motor control centres and distribution boards, it puts 5mm of tested insulating vinyl under the operator's feet, with a broad-ribbed tread so the same mat is also the safe, slip-resistant standing surface for the job.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mb-8 text-lg richtext story-text\"\u003e\n\u003cp\u003eIt is the extra-thick grade of our ribbed vinyl safety matting. Tested to ASTM D178 it achieved an overall \u003cstrong\u003eClass 1, Type IIB\u003c\/strong\u003e rating with a maximum working voltage of \u003cstrong\u003e7,500 V AC\u003c\/strong\u003e, and Type IIB means the compound also passed the flame-resistance test. Choose light grey, blue, brown or black; every colour comes as a 10m × 1m roll that cuts on site to the length of the switch room.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-8\"\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"glance-heading\"\u003e7,500 V AC WORKING VOLTAGE\u003c\/h4\u003e\n\u003cdiv class=\"richtext story-text\"\u003e\n\u003cp\u003eTested to ASTM D178, overall Class 1, Type IIB. Class 1 is rated for a maximum use voltage of 7,500 V AC, which covers every low-voltage installation and most 3.3 kV and 6.6 kV switchgear.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"glance-heading\"\u003eEXTRA THICK, 5MM\u003c\/h4\u003e\n\u003cdiv class=\"richtext story-text\"\u003e\n\u003cp\u003eA full millimetre thicker than the standard 4mm grade, at 5.5 kg\/m². The extra section is what lifts the rating and gives the mat a longer service life in front of busy panels.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"glance-heading\"\u003eBROAD-RIB GRIP\u003c\/h4\u003e\n\u003cdiv class=\"richtext story-text\"\u003e\n\u003cp\u003eTextured broad ribs along the roll give a firm footing for an engineer working with both hands inside a panel, and channel dust and small spills away from the standing area.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch4 class=\"glance-heading\"\u003eFLAME RESISTANT, CHEMICAL RESISTANT\u003c\/h4\u003e\n\u003cdiv class=\"richtext story-text\"\u003e\n\u003cp\u003eDid not ignite in ASTM D1692 testing (Type IIB). Resistant to most acids, alkalis and oils. Phthalate free, REACH SVHC free and 100% recyclable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eWHICH GRADE?\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eExtra-thick switchboard matting (this page)\u003c\/th\u003e\n\u003cth\u003eStandard 4mm ribbed vinyl\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5mm\u003c\/td\u003e\n\u003ctd\u003e4mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eASTM D178 rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 1, Type IIB, 7,500 V AC working voltage\u003c\/td\u003e\n\u003ctd\u003eClass 0, 1,000 V AC working voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kg\/m²\u003c\/td\u003e\n\u003ctd\u003e4.4 kg\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChoose it for\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSwitch rooms, MCCs, HV and LV switchgear, plant rooms where a rated mat is specified\u003c\/td\u003e\n\u003ctd\u003eGeneral ribbed safety flooring where a low-voltage rating is enough\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRule of thumb:\u003c\/strong\u003e if the mat is going in front of switchgear and someone will ask for the rating, buy this grade. It is the one with the paperwork to match. Tell us if your site requires certification to BS EN 61111 rather than ASTM D178 and we will confirm before you order.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eHOW MUCH DO I NEED?\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10m × 1m roll\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCovers \u003cstrong\u003e10 m²\u003c\/strong\u003e. About 55 kg. Runs the full length of a typical switch room in one piece, 1m deep along the panel front.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlanning the run\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeasure the length of the panel front and add 0.5m each end so the mat extends past the outermost door. One metre of depth covers the operating position; for withdrawable breakers or deep-drawout gear, lay two widths side by side.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorked example\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA 7m switchboard: 7m plus 0.5m each end = 8m of roll, leaving 2m for the distribution board in the corridor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCut lengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot listed here. Send us the lengths and we will price them cut to size.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eCOLOURS\u003c\/h4\u003e\n\u003cp\u003eFour stock colours, the same mat and the same price in each. Use the colour selector above to see each one in place.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight grey\u003c\/strong\u003e — the switch-room standard. Shows dropped fixings and tools at a glance and keeps a plant room looking clean.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlue\u003c\/strong\u003e — marks the operating zone clearly on a grey floor; a common choice where the site colour-codes safety areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrown\u003c\/strong\u003e — hides soiling in workshops and transport maintenance bays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack\u003c\/strong\u003e — disappears in front of dark cabinets and on dark floors; the usual choice for retrofit runs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOther colours are produced to order for larger projects.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eTYPICAL APPLICATIONS\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIn front of low-voltage switchboards, motor control centres and distribution boards\u003c\/li\u003e\n\u003cli\u003eHV and LV switch rooms and substations up to the rated working voltage\u003c\/li\u003e\n\u003cli\u003eControl rooms, plant rooms and electrical workshops\u003c\/li\u003e\n\u003cli\u003eTest bays and repair benches where live equipment is worked on\u003c\/li\u003e\n\u003cli\u003eBattery rooms, UPS rooms and data-centre power rooms\u003c\/li\u003e\n\u003cli\u003eTransport maintenance and traction workshops\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eTECHNICAL SPECIFICATION\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComposition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible polyvinyl chloride (PVC), 100% vinyl, phthalate free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTextured broad-rib, ribs running along the roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5mm (13\/64\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoll size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10m × 1m (10 m²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerances\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeight ±0.5mm  |  length 0 \/ +0.3m  |  width ±1cm. All dimensions nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 kg\/m² (1.26 lb\/sq.ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColours\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight grey, blue, brown or black. Other colours to order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical (ASTM D178)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverall Class 1, Type IIB. Maximum working voltage 7,500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire (ASTM D1692)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDid not ignite, Type IIB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile strength (ASTM D178)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,127 psi (Type I and II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElongation (ASTM D178)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256% (Type I and II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTension set (ASTM D178)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture absorption (ASTM D178)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+0.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-23°C to +60°C. Slight size variation may occur at temperature extremes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant to most acids, alkalis and oils — ask for the chemical resistance sheet if you need a specific check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant to PVC degradation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllow up to 2% thermoplastic shrinkage when cutting to a fixed length; faster in hot locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% recyclable; contains no SVHC substances under REACH; phthalate free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eFOR SPECIFIERS\u003c\/h4\u003e\n\u003cp\u003eSuggested clause: \u003cem\u003eElectrical insulating switchboard matting, flexible PVC, broad-rib textured surface, 5mm thick, 5.5 kg\/m², tested to ASTM D178 overall Class 1 Type IIB with a maximum working voltage of 7,500 V AC, flame resistant to ASTM D1692, service temperature -23°C to +60°C, phthalate free, REACH SVHC free, loose laid along the operating face of the switchgear. 10m × 1m rolls, colour [light grey \/ blue \/ brown \/ black].\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTell us the switchgear voltage, the length of the panel front and the room layout and we will return a marked-up quantity and the data sheet.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eINSTALLATION\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLay it loose.\u003c\/strong\u003e Unroll along the operating face of the switchgear and let it relax flat. The weight and the ribbed underside hold it in place; no adhesive is needed and none should be used, because a bonded mat cannot be lifted for inspection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover the whole operating position.\u003c\/strong\u003e The mat should extend past the outermost panel door at each end and be deep enough that the operator's feet stay on it with the door open.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCut on site.\u003c\/strong\u003e A sharp knife along a straightedge. Cut fractionally long to allow for reversion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep it as one piece\u003c\/strong\u003e where you can. Where two lengths must meet, butt them tightly; never overlap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect it.\u003c\/strong\u003e Check the mat for cuts, embedded metal and contamination as part of the switch-room inspection routine, and replace any damaged length.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eCLEANING \u0026amp; MAINTENANCE\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eRoutine:\u003c\/strong\u003e vacuum or sweep along the ribs, then damp mop. Non-porous vinyl, nothing soaks in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDeeper clean:\u003c\/strong\u003e an alkaline floor cleaner diluted to the maker's instructions, rinsed off. Avoid solvents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOil and coolant:\u003c\/strong\u003e wipe up promptly. The compound resists oils, but a contaminated surface is a slip surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eFREQUENTLY ASKED QUESTIONS\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does Class 1, Type IIB mean?\u003c\/strong\u003e\u003cbr\u003eASTM D178 grades insulating matting by the voltage it is proved against. Class 1 is rated for a maximum working voltage of 7,500 V AC. Type II means the compound also passed additional tests, and the B suffix is the flame-resistance test. This mat passed all of them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it certified to BS EN 61111?\u003c\/strong\u003e\u003cbr\u003eIt is tested and rated to ASTM D178, the American standard, which is widely accepted on UK sites. If your site or client specifies BS EN 61111 class matting, tell us before ordering and we will confirm what can be supplied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference from the standard ribbed vinyl?\u003c\/strong\u003e\u003cbr\u003eThickness and rating. The standard grade is 4mm and rated Class 0 at 1,000 V AC. This grade is 5mm and rated Class 1 at 7,500 V AC, and it wears longer in front of busy panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I glue it down?\u003c\/strong\u003e\u003cbr\u003eDo not. It is designed to be loose laid so it can be lifted for inspection and cleaning. Its weight and ribbed underside keep it in place.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it anti-static or ESD matting?\u003c\/strong\u003e\u003cbr\u003eNo, it is the opposite. This mat insulates the person from ground. For electronics benches where static must be drained away, use our \u003ca href=\"\/products\/esd-anti-static-anti-fatigue-matting-9mm\"\u003eESD anti-static matting\u003c\/a\u003e instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I cut it?\u003c\/strong\u003e\u003cbr\u003eA sharp utility knife along a straightedge, on a sacrificial board. Or ask us to cut lengths before dispatch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it come in other sizes?\u003c\/strong\u003e\u003cbr\u003eThe 10m × 1m roll is stocked. Cut lengths are supplied to order, and other colours can be produced for larger projects.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"mt-8 richtext story-text\"\u003e\n\u003ch4 class=\"glance-heading\"\u003eNOT SURE WHAT YOU NEED?\u003c\/h4\u003e\n\u003cp\u003eSend us the switchgear voltage, the length of the panel front and a photo of the room. We will confirm the grade, the colour and the number of rolls, and price any cut lengths.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Industrial Polymers UK","offers":[{"title":"Light grey \/ 10m × 1m roll (10m²)","offer_id":56470856663419,"sku":"IPM-FTX-LGY-10X1","price":605.38,"currency_code":"GBP","in_stock":true},{"title":"Blue \/ 10m × 1m roll (10m²)","offer_id":56470856696187,"sku":"IPM-FTX-BLU-10X1","price":605.38,"currency_code":"GBP","in_stock":true},{"title":"Brown \/ 10m × 1m roll (10m²)","offer_id":56470856728955,"sku":"IPM-FTX-BRN-10X1","price":605.38,"currency_code":"GBP","in_stock":true},{"title":"Black \/ 10m × 1m roll (10m²)","offer_id":56470856761723,"sku":"IPM-FTX-BLK-10X1","price":605.38,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7776\/6024\/files\/switchboard-matting-light-grey-electrician-80657ce3-c4c6-4701-913d-fd2ceb6f7595.jpg?v=1790323116","url":"https:\/\/industrial-polymers.co.uk\/products\/switchboard-matting-5mm-electrical-insulation-7500v-ribbed-pvc","provider":"Industrial-polymers ","version":"1.0","type":"link"}